| 29 | 0 | 26 |
| 下载次数 | 被引频次 | 阅读次数 |
植入式脑机接口(implanted brain-computer interface,iBCI)系统近年来在结构设计与材料集成方面迅速发展,呈现出多路径策略、多材料体系与多功能融合的演化趋势。本文聚焦于iBCI系统中的植入路径选择与电极材料结构优化两大关键方向,系统归纳了硬脑膜外、硬脑膜下、血管内和脑池空间四类典型技术路径的结构特征与应用场景,并分析了各类方案在信号采集能力、生物相容性与微创性之间的权衡机制。在材料与结构层面,重点讨论了柔性基底材料、导电高分子材料及多材料复合结构对电极界面性能与双向功能(采集与刺激)稳定性的影响。通过对代表性方案的归纳与比较,本文构建了面向长期稳定性与系统微创化协同优化的技术框架,为下一代高性能iBCI系统的设计与临床转化提供系统性总结与理论参考。
Abstract:Implanted brain–computer interface(iBCI) systems have seen rapid advancements in structural design and material integration in recent years, exhibiting an evolutionary trend characterized by multi-path strategies, diverse material systems and multifunctional integration. This paper focuses on two key aspects of iBCI systems: implantation pathway selection and structural optimization of electrode materials. It systematically categorizes the structural characteristics and application scenarios of four representative technical pathways—epidural, subdural, endovascular and cisternal, while analyzing the trade-offs among signal acquisition capability, biocompatibility, and minimally invasive properties. In terms to the material and structure, the discussion centers on the impact of flexible substrate materials, conductive polymers, and multi-material composite structures on electrode interface performance and the stability of bidirectional(recording and stimulation) functions. By summarizing and comparing representative solutions, this paper proposes a technological framework aimed at the synergistic optimization of long-term stability and minimally invasive system design, providing a comprehensive overview and theoretical reference for the development and clinical translation of next-generation high-performance iBCI systems.
[1] Limousin P, Foltynie T. Long-term outcomes of deep brain stimulation in Parkinson disease[J]. Nat Rev Neurol, 2019, 15(4): 234-242. DOI: 10.1038/s41582-019-0145-9.
[2] Willett F R, Kunz E M, Fan C, et al. A high-performance speech neuroprosthesis[J]. Nature, 2023, 620(7976): 1031-1036. DOI: 10.1038/s41586-023-06377-x.
[3] Lorach H, Galvez A, Spagnolo V, et al. Walking naturally after spinal cord injury using a brain–spine interface[J]. Nature, 2023, 618(7963): 126-133. DOI: 10.1038/s41586-023-06094-5.
[4] Woeppel K, Hughes C, Herrera A J, et al. Explant analysis of utah electrode arrays implanted in human cortex for brain-computer-interfaces[J]. Front Bioeng Biotechnol, 2021, 9: 759711. DOI: 10.3389/fbioe.2021.759711.
[5] Colachis S C, Dunlap C F, Annetta N V, et al. Long-term intracortical microelectrode array performance in a human: a 5 year retrospective analysis[J]. J Neural Eng, 2021, 18(4): 0460d7. DOI: 10.1088/1741-2552/ac1add.
[6] Kim S, Callier T, Tabot G A, et al. Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex[J]. Proc Natl Acad Sci USA, 2015, 112(49): 15202-15207. DOI: 10.1073/pnas.1509265112.
[7] Kipke D R, Vetter R J, Williams J C, et al. Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex[J]. IEEE Trans Neural Syst Rehabil Eng, 2003, 11(2): 151-155. DOI: 10.1109/TNSRE.2003.814443.
[8] Vetter R J, Williams J C, Hetke J F, et al. Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex[J]. IEEE Trans Biomed Eng, 2004, 51(6): 896-904. DOI: 10.1109/TBME.2004.826680.
[9] Choi J R, Kim S M, Ryu R H, et al. Implantable neural probes for brain-machine interfaces—current developments and future prospects[J]. Exp Neurobiol, 2018, 27(6): 453-471. DOI: 10.5607/en.2018.27.6.453.
[10] Kim C, Jeong J, Kim S J. Recent progress on non-conventional microfabricated probes for the chronic recording of cortical neural activity[J]. Sensors, 2019, 19(5): 1069. DOI: 10.3390/s19051069.
[11] Mestais C S, Charvet G, Sauter-Starace F, et al. WIMAGINE: Wireless 64-channel ECoG recording implant for long term clinical applications[J]. IEEE Trans Neural Syst Rehabil Eng, 2015, 23(1): 10-21. DOI: 10.1109/TNSRE.2014.2333541.
[12] Larzabal C, Bonnet S, Costecalde T, et al. Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients[J]. J Neural Eng, 2021, 18(5): 056026. DOI: 10.1088/1741-2552/ac2003.
[13] Charvet G, Sauter-Starace F, Foerster M, et al. WIMAGINE®: 64-channel ECoG recording implant for human applications[C]. Proceedings of the 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Osaka: IEEE, 2013: 2756-2759.
[14] Naddaf M. Science in 2025: the events to watch for in the coming year[J]. Nature, 2025, 637(8044): 9-11. DOI: 10.1038/d41586-024-03943-9.
[15] Minev I R, Musienko P, Hirsch A, et al. Electronic dura mater for long-term multimodal neural interfaces[J]. Science, 2015, 347(6218): 159-163. DOI: 10.1126/science.1260318.
[16] Bloch J, Lacour S P, Courtine G. Electronic dura mater meddling in the central nervous system[J]. JAMA Neurol, 2017. DOI: 10.1001/jamaneurol.2016.5767.
[17] Schiavone G, Fallegger F, Kang X, et al. Soft, implantable bioelectronic interfaces for translational research[J]. Adv Mater, 2020, 32(17): 1906512. DOI: 10.1002/adma.201906512.
[18] Benbuk A, Gulick D, Moniz-Garcia D, et al. Wireless stimulation of motor cortex through a collagen dura substitute using an ultra-thin implant fabricated on parylene/PDMS[J]. IEEE Trans Biomed Circuits Syst, 2024, 18(2): 334-346. DOI: 10.1109/TBCAS.2023.3329447.
[19] Lee J M, Pyo Y W, Kim Y J, et al. The ultra-thin, minimally invasive surface electrode array NeuroWeb for probing neural activity[J].Nat Commun, 2023, 14(1): 7088. DOI: 10.1038/s41467-023-42860-9.
[20] Hettick M, Ho E, Poole A J, et al. The layer 7 cortical interface: a scalable and minimally invasive brain–computer interface platform[A/OL]. (2022-01-02)[2024-12-20]. http://biorxiv.org/lookup/doi/10.1101/2022.01.02.474656. DOI: 10.1101/2022.01.02.474656.
[21] Neuroscience P. Precision neuroscience receives FDA clearance for highresolution cortical electrode array[EB/OL]. (2025-04-17)[2025-04-21]. https://www.globenewswire.com/news-release/2025/04/17/3063418/0/en/Precision-Neuroscience-Receives-FDA-Clearance-for-High-Resolution-Cortical-Electrode-Array.html.
[22] Musk E, Neuralink. An integrated brain-machine interface platform with thousands of channels[J]. J Med Internet Res, 2019, 21(10): e16194. DOI: 10.2196/16194.
[23] Naddaf M, DREW L. Second brain implant by Elon Musk’s Neuralink: will it fare better than the first?[J]. Nature, 2024, 632(8025): 481-482. DOI: 10.1038/d41586-024-02368-8.
[24] Jun J J, Steinmetz N A, Siegle J H, et al. Fully integrated silicon probes for high-density recording of neural activity[J]. Nature, 2017, 551(7679): 232-236. DOI: 10.1038/nature24636.
[25] Steinmetz N A, Aydin C, Lebedeva A, et al. Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings[J]. Science, 2021, 372(6539): eabf4588. DOI: 10.1126/science.abf4588.
[26] Luo T Z, Bondy A G, Gupta D, et al. An approach for long-term, multi-probe Neuropixels recordings in unrestrained rats[J]. eLife, 2020, 9: e59716. DOI: 10.7554/eLife.59716.
[27] Paulk A C, Kfir Y, Khanna A R, et al. Large-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex-[J]. Nat Neurosci, 2022, 25(2): 252-263. DOI: 10.1038/s41593-021-00997-0.
[28] Coughlin B, Muñoz W, Kfir Y, et al. Modified Neuropixels probes for recording human neurophysiology in the operating room[J]. Nat Protoc, 2023, 18(10): 2927-2953. DOI: 10.1038/s41596-023-00871-2.
[29] Brannigan J F M, Fry A, Opie N L, et al. Endovascular braincomputer interfaces in poststroke paralysis[J]. Stroke, 2024, 55(2): 474-483. DOI: 10.1161/STROKEAHA.123.037719.
[30] Kim R, Lycke R, Luan L, et al. Low-threshold, high-resolution, chronically stable intracortical microstimulation by ultraflexible electrodes[J]. Cell Reports, 2023, 42(7): 112702. DOI: 10.1016/j.celrep.2023.112702.
[31] Yasar T B, Gombkoto P, Vyssotski A L, et al. Months-long tracking of neuronal ensembles spanning multiple brain areas with UltraFlexible Tentacle Electrodes[J].Nat Commun, 2024, 15(1): 4822. DOI: 10.1038/s41467-024-49038-w.
[32] Sanger Z T, Henry T R, Park M C, et al. Neural signal data collection and analysis of Percept™ PC BrainSense recordings for thalamic stimulation in epilepsy[J]. J Neural Eng, 2024, 21(1): 016027. DOI: 10.1088/1741-2552/ad1dc3.
[33] Oxley T J, Opie N L, John S E, et al. Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity[J]. Nat Biotechnol, 2016, 34(3): 320-327. DOI: 10.1038/nbt.3428.
[34] Opie N L, Ronayne S M, Rind G S, et al. Mechanical suitability of an endovascular braincomputer interface[C]. Proceedings of the 2020 8th International Winter Conference on Brain-Computer Interface (BCI). Gangwon, Korea: IEEE, 2020: 1-6. DOI: 10.1109/BCI48061.2020.9061643.
[35] Opie N L, John S E, Rind GS, et al. Focal stimulation of the sheep motor cortex with a chronically implanted minimally invasive electrode array mounted on an endovascular stent[J]. Nat Biomed Eng, 2018, 2(12): 907-914. DOI: 10.1038/s41551-018-0321-z.
[36] Han J J. Synchron receives FDA approval to begin early feasibility study of their endovascular, brain‐computer interface device[J]. Artif Organs, 2021, 45(10): 1134-1135. DOI: 10.1111/aor.14049.
[37] Oxley T J, Yoo P E, Rind G S, et al. Motor neuroprosthesis implanted with neurointerventional surgery improves capacity for activities of daily living tasks in severe paralysis: first in-human experience[J]. J Neurointerv Surg, 2021, 13(2): 102-108. DOI: 10.1136/neurint-surg-2020-016862.
[38] Mitchell P, Lee S C M, Yoo P E, et al. Assessment of safety of a fully implanted endovascular brain-computer interface for severe paralysis in 4 patients: the stentrode with thought-controlled digital switch (SWITCH) study[J]. JAMA Neurol, 2023, 80(3): 270-278. DOI: 10.1001/jamaneurol.2022.4847.
[39] David P, Shahram M, Noam H. Results of the COMMAND trial: an early feasibility study of the synchron endovascular brain-computer interface [EB/OL]. [2025-03-26]. https://www.cns.org/poster2024?id=47238.
[40] John S E, Apollo N V, Opie N L, et al. In vivo impedance characterization of cortical recording electrodes shows dependence on electrode location and size[J]. IEEE Trans Biomed Eng, 2019, 66(3): 675-681. DOI: 10.1109/TBME.2018.2854623.
[41] Tarigoppula V S A, Rind G S, Ronayne S M, et al. Safe retrieval of a stent-based endovascular neural recording array[C]. Proceedings of the 2023 11th International IEEE/EMBS Conference on Neural Engineering (NER). Baltimore, USA: IEEE, 2023. DOI: 10.1109/NER52421.2023.10123895.
[42] Zhang A, Mandeville E T, Xu L, et al. Ultra-flexible endovascular probes for brain recording through micron-scale vasculature[A/OL]. (2023-03-23)[2025-01-11]. http://biorxiv.org/lookup/doi/10.1101/2023.03.20.533576. DOI: 10.1101/2023.03.20.533576.
[43] Wang X, Wu S, Yang H, et al. Intravascular delivery of an ultraflexible neural electrode array for recordings of cortical spiking activity[J]. Nat Commun, 2024, 15(1): 9442. DOI: 10.1038/s41467-024-53720-5.
[44] Ognard J, El Hajj G, Verma O, et al. Advances in endovascular brain computer interface: systematic review and future implications[J]. J Neurosci Methods, 2025, 420: 110471. DOI: 10. 1016/j.jneumeth.2025.110471.
[45] Chen J C, Dhuliyawalla A, Garcia R, et al. Endocisternal interfaces for minimally invasive neural stimulation and recording of the brain and spinal cord[J]. Nat Biomed Eng, 2025, 9(6):896-904. DOI: 10.1038/s41551-024-01281-9.
[46] Chen N, Luo B, Patil A C, et al. Nanotunnels within poly(3,4-ethylenedioxythiophene)-carbon nanotube composite for highly sensitive neural interfacing[J]. ACS Nano, 2020, 14(7): 8059-8073. DOI: 10.1021/acsnano.0c00672.
[47] Wu Y, Wang L, Yan M, et al. Poly(3,4‐ethylenedioxythiophene)/functional gold nanoparticle films for improving the electrode‐neural interface[J]. Adv Healthc Mater, 2024, 13(23): e2400836. DOI: 10.1002/adhm.202400836.
[48] Sharafkhani N, Kouzani A Z, Adams S D, et al. Neural tissue-microelectrode interaction: brain micromotion, electrical impedance, and flexible microelectrode insertion[J]. J Neurosci Methods, 2022, 365: 109388. DOI: 10.1016/j.jneumeth.2021.109388.
[49] Subbaroyan J, Martin D C, Kipke D R. A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex[J]. J Neural Eng, 2005, 2(4): 103-113. DOI: 10.1088/1741-2560/2/4/006.
[50] Wang J, Wang T, Liu H, et al. Flexible electrodes for brain-computer interface system[J]. Adv Mater, 2023, 35(47): 2211012. DOI: 10.1002/adma.202211012.
[51] Fattahi P, Yang G, Kim G, et al. A review of organic and inorganic biomaterials for neural interfaces[J]. Adv Mater, 2014, 26(12): 1846-1885. DOI: 10.1002/adma.201304496.
[52] Tringides C M, Mooney D J. Materials for implantable surface electrode arrays: current status and future directions[J]. Adv Mater, 2022, 34(20): 2107207. DOI: 10.1002/adma.202107207.
[53] Li J, Cheng Y, Gu M, et al. Sensing and stimulation applications of carbon nanomaterials in implantable brain-computer interface[J]. Int J Mol Sci, 2023, 24(6): 5182. DOI: 10.3390/ijms24065182.
[54] Zheng X S, Tan C, Castagnola E, et al. Electrode materials for chronic electrical microstimulation[J]. Adv Healthc Mater, 2021, 10(12): 2100119. DOI: 10.1002/adhm.202100119.
[55] Shi D, Narayanan S, Woeppel K, et al. Improving the biocompatibility and functionality of neural interface devices with silica nanoparticles[J]. Acc Chem Res, 2024, 57(12): 1684-1695. DOI: 10.1021/acs.accounts.4c00160.
[56] Cogan S F. Neural stimulation and recording electrodes[J]. Annu Rev Biomed Eng, 2008, 10: 275-309. DOI: 10.1146/annurev.bioeng.10.061807.160518.
[57] Ziai Y, Zargarian S S, Rinoldi C, et al. Conducting polymerbased nanostructured materials for brain-machine interfaces[J]. Wiley Interdiscip Rev Nanomed Nanobiotechnol, 2023, 15(5): e1895. DOI: 10.1002/wnan.1895.
[58] Liao M, Cui Q, Hu Y, et al. Recent advances in the application of MXenes for neural tissue engineering and regeneration[J]. Neural Regen Res, 2024, 19(2): 258-263. DOI: 10.4103/1673-5374.379037.
[59] Cho N, Squair J W, Aureli V, et al. Hypothalamic deep brain stimulation augments walking after spinal cord injury[J]. Nat Med, 2024, 30(12):3676-3686. DOI: 10.1038/s41591-024-03306-x.
[60] Martin E, Roberts M, Grigoras I F, et al. Ultrasound system for precise neuromodulation of human deep brain circuits[J].Nat Commun, 2025, 16: 8024. DOI: 10.1038/s41467-025-63020-1.
基本信息:
DOI:10.16289/j.cnki.1002-0837.2026.05004
中图分类号:TN911.7;R318;TB30
引用信息:
[1]林贤杰,史张,杨志刚.植入式脑机接口系统的多路径策略与神经电极材料结构优化进展[J].航天医学与医学工程,2026,37(05):476-484.DOI:10.16289/j.cnki.1002-0837.2026.05004.
基金信息:
国家自然科学基金(No.82202145); 上海市战略前沿专项项目(25DP3200300)-子课题(25DP3200304)
2025-05-21
2025
2025-10-09
2025-12-15
2025
1
2026-10-25
2026-10-25